Other notes:

==========

The following are know issues with SNMP on the CP2000-ZX model when running version v1.1 of ZX software. 

1) All temperatures are reported in the format (Celsius / Fahrenheit) that is selected in the "Advanced, Preferences" tab of the UI.  This is important to note when monitoring temperatures remotely. I would suggest keeping your deployment consistent until this issue is resolved.

2) HW Serial numbers for the Interface and Processor board are not returned.

 Both TPC v2.7 and ZX projectors now support version SNMP v3.0 for added security. CP2000-ZX currently does not ship with SNMP V2.0 support. If you need SNMP v2.0 support for a ZX projector, you need to install the patch_snmp.shar.  Do not install this if you don't need it.  It is highly recommend that all NOC operations migrate to support SNMP v3.0 since many of the new features that Christie may add down the road will require the security level provided by SNMP v3.0.


The ZX uses SNMP v3.0 with the follow security settings.

cdSNMPUser MD5 DefaultSNMP DES DefaultSNMP


User name = cdSNMPUser

Protocol = MD5

Password = DefaultSNMP

Encryption = DES

Encryption Password = DefaultSNMP